The RISH Ducer MXX series of multi-transducers simultaneously measure several variables of an electric power system and process them to produce 2 or 3 or 4 analogue output signals. 2 or 4 digital outputs are available for signaling limits or power meterin
The RISH Ducer MXX series of multi-transducers simultaneously measure several variables of an electric power system and process them to produce 2 or 3 or 4 analogue output signals. 2 or 4 digital outputs are available for signaling limits or power meterin
The RISH Ducer MXX series of multi-transducers
simultaneously measure several variables of an
electric power system and process them to produce
2 or 3 or 4 analogue output signals. 2 or 4 digital
outputs are available for signaling limits or power
metering. For two of the limit outputs up to 3
measurands can be logically combined.
For all heavy-current power system variables
Up to 6 outputs (2A + 4D or 4A + 2D or 2A or 3A
Input voltage up to 693 V (phase-to-phase)
Universal analogue outputs (programmable)
Provision for either snapping the transducer onto top
hat rails or securing it with screws to a wall or pan
For more details please refer datasheet.
The RISH Ducer MXX series of multi-transducers
simultaneously measure several variables of an
electric power system and process them to produce
2 or 3 or 4 analogue output signals. 2 or 4 digital
outputs are available for signaling limits or power
metering. For two of the limit outputs up to 3
measurands can be logically combined.
For all heavy-current power system variables
Up to 6 outputs (2A + 4D or 4A + 2D or 2A or 3A
Input voltage up to 693 V (phase-to-phase)
Universal analogue outputs (programmable)
Provision for either snapping the transducer onto top
hat rails or securing it with screws to a wall or pan
For more details please refer datasheet.
The Transmitter RISH Ducer PT 602 Converts the input variable-a signal from a resistance thermometer Pt 100- to a temperature linear output signal.
Current Transformers With Transducer for the measurement of AC current. Rish CT Ducer a very reliable, efficient and robust current transformer for measurement of AC current. It provides 4 to 20 mA or 0 to 20mA DC output.
Tap position transducer RISH CON TPT coverts resistance to proportional analogue output signal. The purpose of the Tap position transducer is to convert tap position of transformers to equivalent analogue output.
The Rish CON - P transducer is used to measure and convert active, reactive, apparent power, Phase angle & Power Factor of a Single-phase or Three-phase AC system with balanced or unbalanced load into a proportional load independent DC current or v